Yayin da cibiyoyin masana'antu da kadarorin kasuwanci na birane ke neman ingantaccen iko a cikin ƙa'idodin ƙafafu masu ƙanƙanta, 450kVA Cummins diesel generator set yana kafa sabon ma'auni don ƙaramin injiniya da ingantaccen amfani da mai. Yin amfani da fasahar zamani cummins lita 13.0 6ZTAA13-G2 wannan fakitin samar da wutar lantarki mai nauyi, wanda aka tsara bisa ga al'ada don manyan dandamali masu lita 14 ko lita 15, yayin da yake rage nauyi mai yawa da rage yawan amfani da mai har zuwa 10%an ƙera shi don biyan buƙatun aminci da hayaki mai ƙarfi na duniya, janareta dizal ɗinmu na Cummins mai ƙarfin 450kVA yana ba da tsaro na aiki akai-akai a wurare masu zafi masu wahala, shigarwar wurare masu tsayi, da kuma zagayowar aiki mai tsanani.
An haɗa shi da ƙwararren masani a fannin fasaha Leroy-Somer TAL-A473-A alternator (daga Nidec Leroy-Somer), wannan generator na diesel na 450kVA yana samun kudin elektriki mai tsayi gaba daya da kudin sine-wave mai kyau, ta hanyar yin total harmonic distortion (THD) ba suka wata kuma yin amfani da kudin elektriki mai kyau ga mahailloli na elektronik, kudin kariya mai canja shakara, da kudin tattauna na hospital. Ya hada da kudin AMF mai amfani da microprocessor da ke iya aminci da ATS, generator ya zama mai tsayi gaba daya da kudin elektriki na utility da ke ciki kuma yana faruwa da kudin kariya na automatic a lokacin a cikin ƙaramin 10 saniti lokacin da kudin elektriki na utility ta baka. Kullum generator na diesel na Cummins na 450kVA ta kammala amfani da kudin load-bank na factory a dukkanin 25%, 50%, 75%, 100%, da 110% ƙanan kadan na yin amfani don gano cikin lokaci, kuma a sanya shi cikin wani wurin da ke ciki ta hanyar tsayayyen kuskure.


Key Engineering Advantages & Competitive Selling Points
1. Mota na diesel na Dongfeng Cummins 6ZTAA13-G2 mai mahallin zahiri
Mota na diesel na Cummins na 450kVA wacce ke cikin wani wurin da ke ciki shine Cummins 6ZTAA13-G2 mota na diesel na ƙwallon 4 da ke cikin wani wurin da ke ciki. Ta hana maki na ƙwallon 6 da ke cikin wani wurin da ke ciki da bore na 130 mm kuma da stroke na 163 mm (ta hana maki na long-stroke), wannan mota na 13.0-liter ya sa maki na torque na farko da kuma ya sa maki na volumetric efficiency mai kyau. Ta hana maki na turbocharger mai mahallin zahiri da Air-to-Air Charge Air Cooling (ATAAC) intercooler, 6ZTAA13-G2 ya zama mai yawa a cikin karamin hawayen da suka shiga, wanda ya nufi da kammalawa ayyukan kuma koyaushe na soot, kuma ya sa ayyukan da suka daga gaba daya ya zama mai kyau. Ya amfani da electronic speed governor mai kyau kuma high-pressure direct fuel injection, wanda ya sa engine ya samu karamin gasoil mai kyau ta hanyar ƙaramin 84–88 L/hr a 100% prime power , wanda ya sa ayyukan da suka daga gaba daya ya zama mai kyau a cikin shekara manya.
Premium Leroy-Somer TAL-A473-A Industrial Alternator
Ayyukan da suka daga gaba daya na karamin elektriki a wannan 450kVA diesel generator set an ba shi zuwa Leroy-Somer TAL-A473-A alternator. An rufe shi da global electric leader Nidec Leroy-Somer, wannan 4-pole brushless synchronous AC alternator an amfani da 2/3 pitch winding configuration mai kyau, wanda ya sa 3rd, 9th, da 15th harmonic voltage distortions ya zama mai kyau ( THD < 2% ). An rufe shi da Class H matsalolin yin kari, tsarin yin kari ta hanyar fukara (VPI), da IP23 kari na matakai, ya zama mai tsaya ga jihar gida na sarrafa. Ya amfani da tsarin yin kari na karama ta hanyar karama (AVR) wanda ke cikin zamanin yanzu, ya samu kari na karama ta hanyar karama a cikin +/-0.5% zuwa +/-1.0% daga cikin wadanda suka fiye AREP+ kari na karama ta hanyar karama, alteneta ya zama mai tsaya ga 300% ƙaramin yadda na kariya a cikin 10 saniti , ya sanya kari ga karama ta hanyar karama don karama na karama ta hanyar karama wadanda suka fiye kamar chillers, overhead cranes, da deep-well water pumps ba tare biyan karama.
3. Tsarin yin kari na karama ta hanyar karama na AMF
Yin kari na karama ya faru da tsarin yin kari na karama ta hanyar karama (standard da SmartGen HGM6120N or Deep Sea DSE6120 an kafa a cikin wani karami na gaba daya don fuskantar da kuma tattara alama na gida, wanda ya nuna 3-phase grid voltage da 3-phase generator output. A lokacin da alama na gida ta dace, ko yanzu a lokacin da voltage ya zoro, ko yanzu a lokacin da voltage ya fi, ko yanzu a lokacin da phase ya kare, wani controller ya amfani da 450kVA diesel generator don fara, don samun voltage/frequency na gaba, da don sao Automatic Transfer Switch (ATS) a a cikin ƙaramin 10 saniti wani LCD screen mai kaza da kaza ya nuna real-time telemetry wanda ke cikin line/phase voltage, current, active power, reactive power, power factor, engine oil pressure, coolant temperature, running hours, da battery charging health, wanda ya kashe da multi-level automatic emergency shutdowns don hana abubuwa na gaba.
4. High-Integrity Base Skid with 95% Vibration Isolation
Kullum 450kVA Cummins generator assembly an yi gabe a cikin rigid, high-tensile structural steel chassis wanda ake so a yin amfani da automated robotic welding. specialized heavy-duty elastomeric rubber shock absorbers su kare engine da alternator daga chassis, su kare kari 95% na mechanical harmonic vibration transfer . Wannan structural integrity ya sa yadda ake sauke a cikin installation footprint, ya kare building floor resonance, da ya rage yadda ake sauke a cikin internal piping life. Chassis zai iya aikawa da optional double-wall base fuel tank da 8 zuwa 12 hours na continuous full-load runtime, wanda yana da mechanical level float indicators, breather caps, drain plugs, da internal leak containment basins.
5. Heavy-Duty 50°C Ambient Tropical Radiator Package
Amma ba ake amfani da standard generator sets wanda su ke da lightweight 40°C cooling units wanda su ke kara thermal derating a lokacin yaki, amma 450kVA Cummins diesel generator set ta mu ya ke da kuma da 50°C tropical radiator package . Ta hana kuma gaba daya na koperi/aluminum na kula, kura na intercooler radiator, kura na wata mai yawa, da fans na kula mai yawa, wannan shirin ya zama maimakon kariya 450kVA na kariya a tsakiya ba tare nin kula a yankin daji na tropiki, yankin kasa na Middle East, ko a sallan basemant na boiler.


Paramita |
Ƙima |
Samfur |
CDC450L |
Kawai na wakilu |
400KVA/320KW |
Kawai na kasa |
450KVA/360KW |
Takwasar kuma tafkin yin aiki |
50Hz/1500rpm, 60Hz/1800rpm |
Tali na fasila |
3 phase 4 wire |
Fakar watsiya |
0.8 (lagging) |
Tsarin injin |
Cummins 6ZTAA13-G2 |
Cylinders |
6 |
Bore x Stroke (mm) |
130 x 163mm |
Compression ratio |
17 : 1 |
Tare daidaiya |
Ya sauke da ruwa |
Tare daidaita |
yi fitilin da kuma DC na 24V |
Madadin |
Stamford / Leroy-Somer / Tooplinks |
Saiwanda makarantar |
DeepSea / Smartgen |
Tashar rayuwa |
110V-440V |
Ƙungiyar rufi |
Class H |
Takaddun Tattara |
IP23 (maimakon), IP55 (ba da shi kuma) |
Tsawon abu (L×W×H) |
4300 x 1600 x 2250mm |
Karama (KGS) |
4200kg |
Kawai |
ATS (sistem na gudanar da tsarin) |
Kwakwaye (dB) |
≤ 72dB@7m |
MOQ |
1 rubu |

Tambaya 1: Wane ne suka fiye da ala'adu na amfani na Cummins 6ZTAA13-G2 don hanyar yadda ya ke cikin 14L/15L na farko?
A:13.0L 6ZTAA13-G2 ya yi amfani da geometry na cylinder na farko da 130×163mm da injection na elektronik, ta hana 450kVA a wani kariya mai yawa da kariya mai yawa. Ya rage kudin kura zuwa 84–88 L/hr a kariya mai yawa—ya rage kudin diesel zuwa 10% don hanyar yadda ya ke cikin engine na farko da kariya mai yawa.
Tambaya 2: Wane ne albarkatu na alternator na Leroy-Somer TAL-A473-A don kariya na industriya?
A:Leroy-Somer TAL-A473-A alternator yana da kyau a kuma kuma ta fuskanci na hanyar gudun kariya da kuma kuma ta zama mai tsayi wajen kariya. Idan aka shirya da AREP+ excitation (wanda ke iya zama optional), yana ba da 300% kariya na short-circuit don 10 seconds, wanda ke taimaka wajen kuma kuma ta fuskanci na inductive electric motors (kamar pump, compressor, da chillers) domin kuma kuma ta fuskanci ba tare da kuma kuma ta fuskanci na voltage dips.
Tambaya #3: Zan iya rarraba wannan generator na Cummins na 450kVA don 60Hz frequency da voltages different?
A:Ee. Idan 50Hz (1500 RPM, 400V/230V) shine standard, muna ba da 60Hz (1800 RPM, 440V/480V/220V) configurations ta hanyar 6ZTAA13-G2 engine platform da matching Leroy-Somer alternators domin kuma kuma ta fuskanci na power grids.
Tambaya #4: Kamar yadda digital AMF controller ya kuma kuma ta fuskanci da Automatic Transfer Switch (ATS)?
A:Kontrola ya nuna 3-phase kudin gida a kowanne lokaci. Idan ya gano kudin gida ta dace, kudin gida ta yawa, ko kudin gida ta fuskanci, ya bada amfani da kudin gida na Cummins 450kVA don fara, ya ci gaba da kudin gida ta dace, kuma ya amfani da ATS don rarraba kudin gida na kudin gida a cikin 10 seconds.