| Quantity: | |
|---|---|
Cummins
CD-C300KVA/240KW
| MODEL | CD-C218kw/273KVA |
| Powered by Cummins Engine | |
| Prime Power (60HZ) | 218kw/273KVA |
| Standby Power (60HZ) | 240kw/300KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Cummins 6LTAA8.9-G2 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 114X 135 |
| Compression Ratio | 16.0:1 |
| Speed | 1800rpm |
| Cooling Method | Water – cooled |
| Starting Method | 24V DC electrical start |
| 25% Full Load Diesel Consumption (L/H) | 15 |
| 50% Full Load Diesel Consumption (L/H) | 27 |
| 75% Full Load Diesel Consumption (L/H) | 39 |
| 100% Full Load Diesel Consumption (L/H) | 58 |
| Engine Displacement (L) | 4 |
| Inspiration (L) | Turbocharged Intercooled |
| Lube Volume (L) | 14.3 |
| Coolant Volume (L) | 25 |
| Noise (Db) | ≤ 80 |
| Alternator Model | Stanford Type Leateck LTG274L |
| Alternator Power | 218kw/273KVA brushless with AVR |
| Voltage | 220/380 V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2350 |
| Dimensions (L x W x H) mm | 3200*1500*2010 |
| 40FT Container | 4 units |
| Optional | ATS (auto transfer switch) |
| | Auto Battery Charger |
| | Base Fuel Tank (for open type) |
| MODEL | CD-C218kw/273KVA |
| Powered by Cummins Engine | |
| Prime Power (60HZ) | 218kw/273KVA |
| Standby Power (60HZ) | 240kw/300KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Cummins 6LTAA8.9-G2 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 114X 135 |
| Compression Ratio | 16.0:1 |
| Speed | 1800rpm |
| Cooling Method | Water – cooled |
| Starting Method | 24V DC electrical start |
| 25% Full Load Diesel Consumption (L/H) | 15 |
| 50% Full Load Diesel Consumption (L/H) | 27 |
| 75% Full Load Diesel Consumption (L/H) | 39 |
| 100% Full Load Diesel Consumption (L/H) | 58 |
| Engine Displacement (L) | 4 |
| Inspiration (L) | Turbocharged Intercooled |
| Lube Volume (L) | 14.3 |
| Coolant Volume (L) | 25 |
| Noise (Db) | ≤ 80 |
| Alternator Model | Stanford Type Leateck LTG274L |
| Alternator Power | 218kw/273KVA brushless with AVR |
| Voltage | 220/380 V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2350 |
| Dimensions (L x W x H) mm | 3200*1500*2010 |
| 40FT Container | 4 units |
| Optional | ATS (auto transfer switch) |
| | Auto Battery Charger |
| | Base Fuel Tank (for open type) |