| Quantity: | |
|---|---|
perkins
CD-P144KW/180KVA
å±ę§å¼
| MODEL | CD-P144KW/180KVA |
| Powered by Original Uk Perkins Engine | |
| Prime Power (50HZ) | 144KW/180KVA |
| Standby Power (50HZ) | 160kw/200KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Original Uk Perkins 1106A-70TAG3 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 105X 135 |
| Compression Ratio | 16.8:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 12V DC electrical start |
| Full Load Diesel Consumption (L/H) | 39L |
| Engine Displacement (L) | 7.01 |
| Inspiration (L) | Turbocharged Intercooler |
| Lube Volume (L) | 16.5L |
| Coolant Volume (L) | 21L |
| Noise (Db) | ≤ 95 |
| Governor Type | Electrical Governing |
| Alternator Model | LEADTECH OR STAMFORD 274G |
| Alternator Power | 144kw/180kva |
| Voltage | According to customers request |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2000 |
| Dimensions (L x W x H) mm | 2800*1100*1500 SILENT 3300*1100*1800 SUPER SILENT |
| 40FT Container | 8 units (S) |
| 20GP Container | 4 units (S) |
| Optional | |
| | ATS (auto transfer switch) |
| | AMF (auto mains failure) |
| | Battery Charger |
| | SUPER SILENT |
| MODEL | CD-P144KW/180KVA |
| Powered by Original Uk Perkins Engine | |
| Prime Power (50HZ) | 144KW/180KVA |
| Standby Power (50HZ) | 160kw/200KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Original Uk Perkins 1106A-70TAG3 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 105X 135 |
| Compression Ratio | 16.8:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 12V DC electrical start |
| Full Load Diesel Consumption (L/H) | 39L |
| Engine Displacement (L) | 7.01 |
| Inspiration (L) | Turbocharged Intercooler |
| Lube Volume (L) | 16.5L |
| Coolant Volume (L) | 21L |
| Noise (Db) | ≤ 95 |
| Governor Type | Electrical Governing |
| Alternator Model | LEADTECH OR STAMFORD 274G |
| Alternator Power | 144kw/180kva |
| Voltage | According to customers request |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2000 |
| Dimensions (L x W x H) mm | 2800*1100*1500 SILENT 3300*1100*1800 SUPER SILENT |
| 40FT Container | 8 units (S) |
| 20GP Container | 4 units (S) |
| Optional | |
| | ATS (auto transfer switch) |
| | AMF (auto mains failure) |
| | Battery Charger |
| | SUPER SILENT |