| Quantity: | |
|---|---|
perkins
CD-P160KW/200KVA
å±ę§å¼
| MODEL | CD-P200KVA |
| Powered by Original Uk Perkins Engine | |
| Prime Power (50HZ) | 160KW/200KVA |
| Standby Power (50HZ) | 176kw/220KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Original Uk Perkins 1106A-70TAG4 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 105X 135 |
| Compression Ratio | 16:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 12V DC electrical start |
| Full Load Diesel Consumption (L/H) | 45.2L |
| Engine Displacement (L) | 7.01L |
| Inspiration (L) | Turbocharged Intercooler |
| Lube Volume (L) | 16.5L |
| Coolant Volume (L) | 21 |
| Noise (Db) | ≤ 80 |
| Governor Type | Electrical Governing |
| Alternator Model | LEADTECH OR STAMFORD 274H |
| Alternator Power | 160kw/200KVA |
| Voltage | 220/380 V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2200 |
| Dimensions (L x W x H) mm | 3100*1300*1600MM SILENT 3500*1300*2000MM SUPER SILENT |
| 40FT Container | 4 units |
| Optional | |
| | ATS (auto transfer switch) |
| | AMF (auto mains failure) |
| | Battery Charger |
| | SUPER SILENT |
| MODEL | CD-P200KVA |
| Powered by Original Uk Perkins Engine | |
| Prime Power (50HZ) | 160KW/200KVA |
| Standby Power (50HZ) | 176kw/220KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | Original Uk Perkins 1106A-70TAG4 |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 105X 135 |
| Compression Ratio | 16:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 12V DC electrical start |
| Full Load Diesel Consumption (L/H) | 45.2L |
| Engine Displacement (L) | 7.01L |
| Inspiration (L) | Turbocharged Intercooler |
| Lube Volume (L) | 16.5L |
| Coolant Volume (L) | 21 |
| Noise (Db) | ≤ 80 |
| Governor Type | Electrical Governing |
| Alternator Model | LEADTECH OR STAMFORD 274H |
| Alternator Power | 160kw/200KVA |
| Voltage | 220/380 V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 2200 |
| Dimensions (L x W x H) mm | 3100*1300*1600MM SILENT 3500*1300*2000MM SUPER SILENT |
| 40FT Container | 4 units |
| Optional | |
| | ATS (auto transfer switch) |
| | AMF (auto mains failure) |
| | Battery Charger |
| | SUPER SILENT |