Standard Warranty
1 year or 1000 hours
The CDP110KVA is Jiuan Generator's 110KVA Perkins diesel generator for commercial prime power. Powered by the Perkins 1104C-44TAG2 — a four-cylinder, 4.4L, turbocharged and air-to-air aftercooled diesel at 18.2:1 compression — the unit delivers 80KW/100KVA ISO8528 PRP prime and 88KW/110KVA standby at 1500 RPM (50Hz). Compact 1700kg / 2600×1100×1600mm footprint for plant room installation. Fuel consumption: 26.9 L/h at full prime load; 260L tank for 8-10h autonomy. EU Stage II / EPA Tier 2; DSE7320 or AMF25 controller; silent canopy ≤75dB(A) at 7m; 18-month warranty.
The CDP110KVA is Jiuan Generator's 110KVA Perkins diesel generator for commercial and campus prime power — delivering 80KW/100KVA ISO8528 PRP continuous and 88KW/110KVA standby for medium commercial buildings, retail parks, school campuses, and light manufacturing facilities where load profiles run in the 60-80KW continuous range. Powered by the four-cylinder 1104C-44TAG2 engine, the CDP110KVA occupies a 2600×1100×1600mm footprint at 1700kg — compact enough for plant room installation within existing building infrastructure without the structural reinforcement typically required for heavier 6-cylinder gensets.
The Perkins 1104C-44TAG2 generator engine is a four-cylinder, four-stroke, turbocharged and air-to-air aftercooled diesel with 4.4L displacement, 105mm × 127mm bore and stroke, and an 18.2:1 compression ratio. The air-to-air aftercooler reduces charge air temperature before injection, improving volumetric efficiency and combustion quality relative to non-aftercooled variants in the same 1104C family. Fuel consumption at 1500 RPM (50Hz): 26.9 L/h at full prime load, 20.2 L/h at 75% load, 14.1 L/h at 50% load. Cold start: -15°C. EU Stage II / EPA Tier 2 certified for global deployment.
At 75% prime load (60KW), the 80KW prime power generator CDP110KVA consumes 20.2 L/h — a specific fuel consumption of approximately 337 mL/kWh, representing the 1104C-44TAG2 engine's most efficient operating band for continuous commercial service. Facilities running at 60-80% of installed generator capacity benefit from the 4-cylinder layout's thermal efficiency at this load range. The brushless synchronous alternator delivers ±1% voltage regulation and THD below 5%, ensuring stable power quality for office HVAC control systems, refrigeration equipment, and data networking infrastructure.
For emergency standby operation, the 110KVA standby power unit CDP110KVA fits a Deep Sea DSE7320 or ComAp AMF25 controller with AMF auto-start, ATS transfer switching, per-phase monitoring, and fault protection covering overload, low oil pressure, high coolant temperature, overspeed, and undervoltage. Three enclosure formats are available: open-frame (dedicated plant room), super silent canopy (≤75dB(A) at 7 meters, for urban retail or campus environments with acoustic requirements), and weatherproof containerized for rooftop or external pad installation. The 260L base fuel tank supports 8-10 hours of prime operation.
The Perkins 1104 series genset 1104C-44TAG2 engine operates on a 500-hour planned service interval for engine oil and filter changes — consistent with the 1100-series maintenance schedule familiar to commercial facility operators. Genuine Perkins 1104C parts — filter kits, belts, and injectors — are available through Perkins' global dealer network. Jiuan Generator conducts a full-load factory test before dispatch and covers each CDP110KVA with an 18-month or 2,000-hour warranty. Optional 4G IoT remote monitoring enables off-site fault alerting and run-hour tracking for facilities with remote management requirements.

| Parameter | Value |
| Model | CDP110KVA |
| Prime Power | 80KW / 100KVA |
| Standby Power | 88KW / 110KVA |
| Engine Model | Perkins 1104C-44TAG2 |
| Cylinders | 4 Inline |
| Displacement | 4.4L |
| Bore × Stroke | 105mm × 127mm |
| Compression Ratio | 18.2:1 |
| Fuel System | Turbocharged, Air-to-Air Aftercooled, Mechanical Governor |
| Emission Standard | EU Stage II / EPA Tier 2 |
| Cold Start | -15°C unassisted |
| Fuel Consumption | 26.9 / 20.2 / 14.1 L/h (Full / 75% / 50% prime) |
| Frequency / Speed | 50Hz / 1500RPM; 60Hz / 1800RPM |
| Phase / Wires | 3-Phase, 4-Wire |
| Voltage Output | 415/240V, 400/230V, 380/220V |
| Power Factor | 0.8 Lagging |
| Starting | 12V DC Electric Start |
| Controller | Deep Sea DSE7320 / ComAp AMF25 (AMF + ATS) |
| Alternator | Stamford / Leroy-Somer / Tooplinks |
| Insulation Class | Class H |
| Protection Rating | IP23 standard / IP55 optional |
| Noise Level | ≤75dB(A) @ 7m (silent canopy) |
| Fuel Tank | 260L integrated base tank |
| Dimensions (L×W×H) | 2600 × 1100 × 1600mm |
| Weight | 1,700kg |
| Optional | ATS Cabinet, Parallel Module, 4G IoT |

1. Right-Sized 80KW Prime — No Oversizing Penalty for Medium Commercial Loads
The 110KVA Perkins diesel generator CDP110KVA delivers 80KW prime at the load band that typical 5,000-15,000 sqm commercial buildings run in daily operation. Avoiding oversizing to a 200+ KW genset running at 30-40% load improves fuel consumption efficiency and reduces life-cycle service costs without under-sizing the facility's power reserve margin.

2. Air-to-Air Aftercooled 1104C Engine — Higher Output from the 4-Cylinder Platform
The Perkins 1104C-44TAG2 generator engine uses air-to-air aftercooling to lower charge air temperature before injection, enabling the 4-cylinder 4.4L engine to achieve 80KW prime output — a power density that non-aftercooled variants of the same block cannot sustain at continuous PRP rating with the same service life margin.
3. Compact 1700kg Footprint — Plant Room Integration Without Structural Works
The 80KW prime power generator CDP110KVA weighs 1700kg and occupies 2600×1100×1600mm — a size class that fits within most existing commercial building plant rooms without the structural reinforcement typically required for 6-cylinder gensets above 250KW, simplifying retrofit generator room projects in occupied commercial buildings.

4. DSE7320 / AMF25 Controller — Dual Controller Option for Site Compatibility
The 110KVA standby power unit CDP110KVA offers Deep Sea DSE7320 or ComAp AMF25 controller — a dual-option that lets facility engineers match the generator controller to the building management system protocol already in use, reducing integration complexity and commissioning time on multi-generator projects or like-for-like replacement installations.
5. 260L Tank — Full Business-Day Autonomy at Prime Load
The Perkins 1104 series genset CDP110KVA carries a 260L integrated fuel tank. At 20.2 L/h at 75% prime load, this provides approximately 12.9 hours of continuous operation — covering a standard business day and evening period without interrupting commercial or retail operations for manual refuelling.

The CDP110KVA 80KW prime power generator serves the following mid-scale commercial and light industrial applications:
Jiuan Generator provides OEM configuration for the CDP110KVA Perkins 1104C-44TAG2 generator. Available options include super silent canopy in custom RAL color, ATS transfer switch cabinet, parallel synchronization module for N+1 redundancy, 4G IoT remote monitoring, and extended fuel tank. All units use genuine Perkins 1104C-44TAG2 parts and pass a full-load factory burn-in test before dispatch.

Q: What is the effective prime operating range for the CDP110KVA?
A: The 110KVA Perkins diesel generator CDP110KVA is rated 80KW/100KVA ISO8528 PRP prime for unrestricted continuous operation. The 88KW/110KVA standby rating applies to emergency backup at up to 200 hours per year. Both ratings use the 1104C-44TAG2 engine at 1500 RPM (50Hz) within the same physical unit.
Q: Can the CDP110KVA operate in parallel with a second unit?
A: The 110KVA standby power unit CDP110KVA supports parallel operation when equipped with a parallel synchronization module and a compatible DSE controller. Parallel configuration allows two CDP110KVA units to share a 160KW+ commercial facility load or provide N+1 redundancy for applications requiring continuous power availability.
Q: What are the service intervals for the 1104C-44TAG2 engine?
A: The Perkins 1104 series genset CDP110KVA requires engine oil and filter changes at 500-hour intervals under normal operating conditions. Fuel injectors, turbocharger, and belt assemblies are checked at 2,000-hour intervals. All service parts are available through Perkins' global authorized dealer network.
The CDP110KVA is Jiuan Generator's 110KVA Perkins diesel generator for commercial prime power. Powered by the Perkins 1104C-44TAG2 — a four-cylinder, 4.4L, turbocharged and air-to-air aftercooled diesel at 18.2:1 compression — the unit delivers 80KW/100KVA ISO8528 PRP prime and 88KW/110KVA standby at 1500 RPM (50Hz). Compact 1700kg / 2600×1100×1600mm footprint for plant room installation. Fuel consumption: 26.9 L/h at full prime load; 260L tank for 8-10h autonomy. EU Stage II / EPA Tier 2; DSE7320 or AMF25 controller; silent canopy ≤75dB(A) at 7m; 18-month warranty.
1 year or 1000 hours
Up to 3 years for Perkins engines;
2 years for Stamford S-series alternators
Professional technical support and spare parts supply network
What every JIUAN generator set delivers — before and after it reaches your site.
Up to 2 years or 2,000 hours of full-unit warranty (whichever comes first), underwritten in cooperation with PICC — giving overseas buyers confidence in every unit.
Guaranteed expedited air shipping — core warranty components arrive worldwide in just 3 to 5 days, keeping your downtime to an absolute minimum.
Soundproof canopies use cold-rolled steel, high-gloss powder coating and flame-retardant insulation for outstanding rust, scratch and noise resistance.
Every unit is brand new with a unique, traceable ESN. Each generator is run through staged full-load and overload tests before shipment.
Configurations for frigid regions, coastal climates and demanding worksites include tailored heating, protection and anti-corrosion solutions.
One-stop customs clearance certificate support and processing helps smooth the path from our factory to your port.
Custom gensets: silent, explosion-proof, custom voltage
Full project tech support & remote monitoring
Track record: data centers, mines, ports, infrastructure
24/7 Genset Service Hotline: +86 18818906850
Add: No.1 Dongxing Xiang, Tanbu Town, Huadu, Guangzhou, China
Fast & reliable response always guaranteed.