Quantity: | |
---|---|
Cummins
CD-C125KVA/100KW
MODEL | CD-C100KW/125KVA |
Powered by Cummins Engine | |
Prime Power (50HZ) | 92KW/115KVA |
Standby Power (50HZ) | 100kw/125KVA |
Power Factor | 0.8 ļ¼Laggingļ¼ |
Phase Wires | 3-phases 4-Wires |
Start Model | Electric |
Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
Engine Model | DCEC Cummins 6BTA5.9-G2 4 Cycle |
Cylinders | 6 |
Cylinder Arrangement | L |
Bore x Stroke(mm) | 102X 120 |
Compression Ratio | 17.5:1 |
Speed | 1500rpm |
Cooling Method | Water – cooled |
Starting Method | 24V DC electrical start |
Full Load Diesel Consumption (L/H) | 25 |
Engine Displacement (L) | 5.9 |
Inspiration (L) | Natural |
Lube Volume (L) | 14.3 |
Coolant Volume (L) | 25 |
Noise (Db) | ≤ 80 |
Alternator Model | Newage Stamford UCI274D or Leadtech LTG274D |
Alternator Power | 96KW/120KVA brushless with AVR |
Voltage | 380/220V,400/230V,415/240V,220/127V |
Protection | IP23 |
Voltage Regulation | ±4% |
Insulation Class | H |
Voltage Control | AVR |
Net Weigh (KGS) | 1400 |
Dimensions (L x W x H) mm | 2600*1000*1700 (S) 3300*1100*1800 (Super Silent) |
Controller | Smartgen 6110 or Deepsea 7320 |
Standard | Muffler * 2PCS |
| Battery 80A * 2 PCS |
Optional | ATS (auto transfer switch) |
| AMF(auto mains failure) |
| Trailer |
MODEL | CD-C100KW/125KVA |
Powered by Cummins Engine | |
Prime Power (50HZ) | 92KW/115KVA |
Standby Power (50HZ) | 100kw/125KVA |
Power Factor | 0.8 ļ¼Laggingļ¼ |
Phase Wires | 3-phases 4-Wires |
Start Model | Electric |
Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
Engine Model | DCEC Cummins 6BTA5.9-G2 4 Cycle |
Cylinders | 6 |
Cylinder Arrangement | L |
Bore x Stroke(mm) | 102X 120 |
Compression Ratio | 17.5:1 |
Speed | 1500rpm |
Cooling Method | Water – cooled |
Starting Method | 24V DC electrical start |
Full Load Diesel Consumption (L/H) | 25 |
Engine Displacement (L) | 5.9 |
Inspiration (L) | Natural |
Lube Volume (L) | 14.3 |
Coolant Volume (L) | 25 |
Noise (Db) | ≤ 80 |
Alternator Model | Newage Stamford UCI274D or Leadtech LTG274D |
Alternator Power | 96KW/120KVA brushless with AVR |
Voltage | 380/220V,400/230V,415/240V,220/127V |
Protection | IP23 |
Voltage Regulation | ±4% |
Insulation Class | H |
Voltage Control | AVR |
Net Weigh (KGS) | 1400 |
Dimensions (L x W x H) mm | 2600*1000*1700 (S) 3300*1100*1800 (Super Silent) |
Controller | Smartgen 6110 or Deepsea 7320 |
Standard | Muffler * 2PCS |
| Battery 80A * 2 PCS |
Optional | ATS (auto transfer switch) |
| AMF(auto mains failure) |
| Trailer |