Quantity: | |
---|---|
MODEL | CD-C480KW/600KVA |
Powered by Cummins Engine | |
Prime Power (50HZ) | 480KW/600KVA |
Standby Power (50HZ) | 550kw/687KVA |
Power Factor | 0.8 (Lagging) |
Phase Wires | 3-phases 4-Wires |
Start Model | Electric |
Fuel Consumption | 97L/h at 100% Load |
Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
Engine Model | CCEC Cummins KTAA19-G6A 4-Cycle |
Cylinders | 6 |
Cylinder Arrangement | L |
Bore x Stroke(mm) | 159X 159 |
Compression Ratio | 13.9:1 |
Speed | 1500rpm |
Cooling Method | Water – cooled |
Starting Method | 24V DC electrical start |
Full Load Diesel Consumption (L/H) | 17 |
Engine Displacement (L) | 19 |
Inspiration (L) | Turbocharged Intercooled |
Lube Volume (L) | 50 |
Coolant Volume (L) | 95 |
Noise (Db) | ≤ 80 |
Alternator Model | Newage Stamford HCI544E or Leadtech LTG354FA |
Alternator Power | 488KW/610KVA Brushles with AVR |
Voltage | 380/220V,400/230V,415/240V,220/127V |
Protection | IP23 |
Voltage Regulation | ±4% |
Insulation Class | H |
Voltage Control | AVR |
Net Weigh (KGS) | 6700 |
Dimensions (L x W x H) mm | 4500*1800*1900 |
Controller | Smartgen 6110 or Deepsea 7320 |
Standard | Muffler * 2PCS |
| Battery 120A * 2 PCS |
Optional | ATS (auto transfer switch) |
| AMF(auto mains failure) |
| Containerized |
MODEL | CD-C480KW/600KVA |
Powered by Cummins Engine | |
Prime Power (50HZ) | 480KW/600KVA |
Standby Power (50HZ) | 550kw/687KVA |
Power Factor | 0.8 (Lagging) |
Phase Wires | 3-phases 4-Wires |
Start Model | Electric |
Fuel Consumption | 97L/h at 100% Load |
Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
Engine Model | CCEC Cummins KTAA19-G6A 4-Cycle |
Cylinders | 6 |
Cylinder Arrangement | L |
Bore x Stroke(mm) | 159X 159 |
Compression Ratio | 13.9:1 |
Speed | 1500rpm |
Cooling Method | Water – cooled |
Starting Method | 24V DC electrical start |
Full Load Diesel Consumption (L/H) | 17 |
Engine Displacement (L) | 19 |
Inspiration (L) | Turbocharged Intercooled |
Lube Volume (L) | 50 |
Coolant Volume (L) | 95 |
Noise (Db) | ≤ 80 |
Alternator Model | Newage Stamford HCI544E or Leadtech LTG354FA |
Alternator Power | 488KW/610KVA Brushles with AVR |
Voltage | 380/220V,400/230V,415/240V,220/127V |
Protection | IP23 |
Voltage Regulation | ±4% |
Insulation Class | H |
Voltage Control | AVR |
Net Weigh (KGS) | 6700 |
Dimensions (L x W x H) mm | 4500*1800*1900 |
Controller | Smartgen 6110 or Deepsea 7320 |
Standard | Muffler * 2PCS |
| Battery 120A * 2 PCS |
Optional | ATS (auto transfer switch) |
| AMF(auto mains failure) |
| Containerized |