| Quantity: | |
|---|---|
Cummins
CD-C344KVA/275KW
| MODEL | CDC275KW/344KVA |
| Powered by CCEC Cummins Engine | |
| Prime Power (50HZ) | 275KW/344KVA |
| Standby Power (50HZ) | 300kw/375KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | CCEC Cummins NTA855-G2A 4-cycle |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 140X 152 |
| Compression Ratio | 14.0:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 24V DC electrical start |
| Full Load Diesel Consumption (L/H) | 62 |
| Engine Displacement (L) | 14 |
| Inspiration (L) | Turbocharged water cooling |
| Lube Volume (L) | 38.6 |
| Coolant Volume (L) | 85 |
| Noise (Db) | ≤ 80 |
| Alternator Model | Newage Stamford UCI444E Brand Leadtech LTG314F |
| Alternator Power | 280KW/350KVA Brushles with AVR |
| Voltage | 380/220V,400/230V,415/240V,220/127V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 3380 |
| Dimensions (L x W x H) mm | 3400*1350*1800 (S) 4450*1530*2250 (Super Silent) |
| Controller | Smartgen 6110 or Deepsea 7320 |
| Standard | Muffler * 2PCS |
| | Battery 120A * 2 PCS |
| Optional | ATS (auto transfer switch) |
| | AMF(auto mains failure) |
| MODEL | CDC275KW/344KVA |
| Powered by CCEC Cummins Engine | |
| Prime Power (50HZ) | 275KW/344KVA |
| Standby Power (50HZ) | 300kw/375KVA |
| Power Factor | 0.8 ļ¼Laggingļ¼ |
| Phase Wires | 3-phases 4-Wires |
| Start Model | Electric |
| Protection | Low oil-pressure, High water temperature, Over-speed, Over-current |
| Engine Model | CCEC Cummins NTA855-G2A 4-cycle |
| Cylinders | 6 |
| Cylinder Arrangement | L |
| Bore x Stroke(mm) | 140X 152 |
| Compression Ratio | 14.0:1 |
| Speed | 1500rpm |
| Cooling Method | Water – cooled |
| Starting Method | 24V DC electrical start |
| Full Load Diesel Consumption (L/H) | 62 |
| Engine Displacement (L) | 14 |
| Inspiration (L) | Turbocharged water cooling |
| Lube Volume (L) | 38.6 |
| Coolant Volume (L) | 85 |
| Noise (Db) | ≤ 80 |
| Alternator Model | Newage Stamford UCI444E Brand Leadtech LTG314F |
| Alternator Power | 280KW/350KVA Brushles with AVR |
| Voltage | 380/220V,400/230V,415/240V,220/127V |
| Protection | IP23 |
| Voltage Regulation | ±4% |
| Insulation Class | H |
| Voltage Control | AVR |
| Net Weigh (KGS) | 3380 |
| Dimensions (L x W x H) mm | 3400*1350*1800 (S) 4450*1530*2250 (Super Silent) |
| Controller | Smartgen 6110 or Deepsea 7320 |
| Standard | Muffler * 2PCS |
| | Battery 120A * 2 PCS |
| Optional | ATS (auto transfer switch) |
| | AMF(auto mains failure) |