65kVA silent diesel genset nke ji SDEC 4ZT4.1-G21 inline 4-cylinder turbo engine, 50Hz 3-phase 400V, PF0.8, nke na-eme ka ISO8528. Nke na-eme ka ọ dị mma maka ịkpọ ọkụ na ịdị ọcha, na-eme ka IP23 brushless alternator. Compact soundproof canopy nke na-eme ka ọ dị mma maka ịgbaghara ọsọ, ịkpọ ọkụ, na ịkpọ akụkụ, na-eme ka ụlọ ịkwu, ụlọ ndị mmadụ na-agba ụzọ, na ụlọ ịkwu nke dị mkpụmkpụ.
Prime 50kVA, standby 55kVA silent genset nke eji SDEC 4ZT3.5-G21 inline 4-cylinder engine iji mechie, 50Hz 3P 400V, PF0.8, nke na-eme ka ISO8528. Turbo design nke na-eme ka ọ dị mma maka ịkpọ ọkụ, na-eme ka IP23 brushless alternator. Compact soundproof canopy nke na-eme ka ọ dị mma maka ịgbaghara ọsọ, ịkpọ ọkụ, na ịkpọ akụkụ, na-eme ka ụlọ ịkwu, ụlọ ndị mmadụ na-agba ụzọ, na ụlọ ịkwu nke dị mkpụmkpụ.
CDS220KVA bụ ọkụ ọbara diesel 220KVA nke Jiuan Generator e jere iji mee maka ọrụ ndị dị mkpa nke ngalaba ndustrial na komesha nke ukwu. E jiri ọkụ SDEC SC8D280D2 nke e nwere isi asaa (inline six-cylinder engine) na-eme ka ọ dị mfe ịgbanwe ụzọ ọbara nke oke (wet cylinder liner design) gbasara ya, ọkụ a nwere ike inye 160KW/200KVA nke prime na 176KW/220KVA nke standby maka ISO8528 PRP na ESP. Nke a bụ ọkụ 200KVA nke prime power nke e nwere ike ịmata ya dị ka ọkụ nke e nwere ike ịgbasara ya nke ọrụ nke ụlọ ọrụ, ụlọ ọgwụ, ụlọ komesha, na ọrụ nke ịgba ọbara nke ọdịda (off-grid mining operations), nke e jiri akwụkwọ ọkụ nke e nwere ike ịkpọ ya (fully sealed soundproof canopy) na ụzọ ọbara 550L nke e jikọtara ya (integrated fuel tank), alternator nke H-class na-eme ka ọ dị mfe ịgbanwe (brushless alternator), na Deepsea DSE7320 controller.
CDS165KVA bụ ọkụ nke Jiuan Generator nke 165KVA nke SDEC nke eji eme ihe na-eme nke diesel, nke eji mee ihe na mpaghara 120–132KW nke ngwaọrụ nke mmadụ na-eme ihe na egwuregwu nke ọdịnala — ọkụ nke eji eme ihe nke ebe obibi nke ọfụma, ngwaọrụ nke mkpọtụ kachasị elu, na egwuregwu nke isi obodo nwere ike ịgbanwe ihe nke ọkụ nke 200KVA nke dị ukwuu. Nke a na-eme ihe na ọkụ nke SDEC SC7H205D2 nke eji eme ihe na-eme nke ọkụ nke 4-valve inline six-cylinder, ọkụ nke 165KVA a na-eme ihe na-eme ihe nke 120KW/150KVA prime na 132KW/165KVA standby na ISO8528 PRP na ESP standards, nke eji eme ihe na-eme nke ≤72dB(A) silent enclosure na ọkụ nke 420L base fuel tank maka ọkụ nke dị n'okpuru nke ọkụ nke dị n'okpuru.
CDP150KVA bụ Jiuan Generator's 150KVA Perkins diesel generator wuru maka ike kachasị na njikere na saịtị ọrụ dịpụrụ adịpụ, ọrụ ndị na-egwupụta akụ, na ụlọ ọrụ azụmahịa ebe nnweta akụkụ na ọrụ na saịtị dị mkpa dị ka mmepụta aha. Kwadoro site na Perkins 1106A-70TG1 engine na ntinye mmanụ ọkụ na-arụ ọrụ, ihe ọkụkụ a na-arụ ọrụ na 150KVA na-enye 108KW/135KVA isi na 120KW/150KVA na-arụ ọrụ na ISO8528 PRP na ụkpụrụ ESP. Na ≤68dB ((A) na mita 7, ọ bụ n'etiti ndị kasị jụụ nkeji na 100150KVA klas adabara obodo azụmahịa nrụnye tinyere ime obodo saịtị deployments.
Nke a nwere ọkụ nke 250KVA na ọkụ nke 275KVA, e jere ya nke Perkins 1206A-E70TTAG3 nke dị ọnụ ụzọ nke ọkụ na ọkụ nke dị ọnụ ụzọ nke ọkụ, e jere ya nke dị ọnụ ụzọ nke ọkụ na ọkụ nke dị ọnụ ụzọ nke ọkụ. E jere ya nke dị ọnụ ụzọ nke ọkụ maka ọkụ nke dị ọnụ ụzọ nke ọkụ. E jere ya nke dị ọnụ ụzọ nke ọkụ maka ọkụ nke dị ọnụ ụzọ nke ọkụ, na ọkụ nke dị ọnụ ụzọ nke ọkụ nke dị ọnụ ụzọ nke ọkụ nke dị ọnụ ụzọ nke ọkụ nke dị ọnụ ụzọ nke ọkụ. E jere ya nke dị ọnụ ụzọ nke ọkụ maka ọkụ nke dị ọnụ ụzọ nke ọkụ na ụlọ ọgwụ, ụlọ ọgwụ, ụlọ ọgwụ, na ụlọ ọgwụ maka ọkụ nke dị ọnụ ụzọ nke ọkụ ma ọ bụ ọkụ nke dị ọnụ ụzọ nke ọkụ.
CDP275KVA bụ ịzọba diesel Perkins nke Jiuan Generator nke 275KVA, e kọrọ ya maka ihe ọ bụla dị ka ihe ọ bụla na ihe ọ bụla nke ọdịnala nke ụlọ ọrụ data, ụlọ ọrụ nke ọtụtụ ụlọ ọrụ, ụlọ ọrụ nke ịkpata ụlọ ọrụ, na ụlọ ọrụ nke ịkpata ụlọ ọrụ. E jiri Perkins 1206A-E70TTAG3 nke nwere turbocharger nke abụọ na-akpata ụda na air-to-air aftercooler, ihe ọ bụla nke CDP275KVA a na-eme ka ọ dịrị 200KW/250KVA na prime na 220KW/275KVA na standby maka ISO8528 PRP na ESP standards. Nke EU Stage II na EPA Tier 2. Ihe ọ bụla nke 400L nke e ji tụọ ọkụ na base fuel tank na-eme ka ọ dịrị 7–9 oru nke ọdịnala na prime load.
CDP275KVA bụ ihe nchịkọta Jiuan 275KVA Perkins nke e jere ihe nchịkọta diesel maka ihe nchịkọta nke mpaghara nchịkọta na ngalaba nke ọrụ nchịkọta. E jiri Perkins 1206A-E70TTAG3 gburugburu ya, nke e jiri electronic governor gbanwee frequency n'okpuru ±0.5% mgbe e gbanwee oke ọrụ, ihe a na-eme ka ọrụ dị iche iche nke site na mpaghara nchịkọta — tower cranes, ihe nchịkọta concrete batching, compressors, na welding sets — mana ọ ghara inwe VFD trips ma ọ bụ ihe nchịkọta nke motor thermal faults nke e mepụtara site na ihe nchịkọta nke mechanical governor frequency excursions. ISO8528 PRP e nyere ya 200KW/250KVA maka ihe nchịkọta nke ọrụ nke ọzọ; ESP e nyere ya 220KW/275KVA maka ihe nchịkọta nke ọrụ nke ọzọ.
CDP200KVA bụ ịkụ ọkụ diesel 200KVA nke Jiuan Generator na-eme ihe nke e nwere ike iji mee ihe dịka ihe nke ọkụ nke ụlọ ọrụ ma ọbụ ihe nke ọkụ nke ọzọ — ụlọ ọrụ, ụlọ ọfice, ụlọ ịkwu ọrụ, na ụlọ ọrụ ndị ọzọ nke ukwuu. Nke a na-akpọ ọkụ nke Perkins 1106A-70TAG3 na-akpọ ọkụ nke air-to-air aftercooled turbocharged induction, ọ na-akpọ ọkụ 144KW ISO8528 PRP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ ma ọbụ 160KW ESP nke ọkụ nke ọzọ maka ọkụ nke ọzọ nke ọgụgụ ọhụrụ. E nwere ike ịkpọ ọkụ EU Stage II. Ihe nke ọkụ nke ọzọ nke silent canopy nke e nwere ike ịkpọ ọkụ ≤75dB(A) na 7m; DSE6120 AMF auto-start na ATS transfer nke e nwere ike ịkpọ ọkụ nke ọzọ nke ọgụgụ ọhụrụ nke ọgụgụ ọhụrụ. Ọkụ nke 400L na-akpọ ọkụ 8–9 hours nke ọkụ nke ọzọ.
CDP50KVA bụ ịsọ ụlọ ọrụ Jiuan nke 50KVA Perkins nke na-eme ihe dị ka ịsọ diesel maka ụlọ ọrụ nke mkpụrụ akụ, obodo nke ụzọ ọkpụkpụ, na ngalaba ndị dị na mpaghara ọkpụkpụ nke enweghị isi mmalite. O nwere ike nke Perkins 1103A-33TG1 — engine nke nwere atọ (3) cylinders, 3.3L nke na-eme ihe dị ka turbocharged, nke na-eme ihe dị ka mechanical governor, na compression ratio nke 17.25:1 — o nwere ike inye 36KW ISO8528 PRP prime power ma ọ bụ 40KW ESP standby na mpaghara nke 2250×1000mm nke dị mfe ma ọ bụrụ na o nwee oke ọkụ 1200kg. O nwere ike nke EPA Tier 2 na EU Stage II. O nwere ike inye ịsọ nke dị ka cold start na -20°C; silent canopy dị ka ≤75dB(A) na 7m; tank nke na-enye ike inye 8–10 hours nke autonomous operation.
CDP250KW bụ ịsọ ụlọ ịsọ 250KW nke Jiuan Generator maka ngwaọrụ nke ọkụ na-eme n'ala, ịkpata ihe nke ọkụ nke ihe ndị ọkụ dị elu, na ịsọ ụlọ ịsọ nke ọkụ nke ụlọ ọrụ dị elu. Ọ dị na Perkins 1706A-E93TAG2 — ụlọ ọrụ nke isi 6, 9.29L nke eji ihe ịsọ elektronik nke ọkụ dị elu na ihe ịsọ nke ọkụ nke ECM — ọ na-eme 250KW ISO8528 PRP nke ịsọ ụlọ ịsọ nke ọkụ na 275KW ESP nke ịsọ ụlọ ịsọ nke ọkụ nke ọkụ nke ọkụ. Ihe ịsọ ọkụ: 52.3 L/h na 100% nke ịsọ ụlọ ịsọ nke ọkụ. Ụlọ ọrụ ọkụ nke 500L nke eji na-eme 9+ ọrụ nke ịsọ ụlọ ịsọ nke ọkụ nke ọkụ. EU Stage II / EPA Tier 2 nke eji na-eme; ụlọ ọrụ nke ọkụ nke ọkụ nke ọkụ ≤75dB(A) na 7m; ọkụ nke 18 ọnwa ma ọ bụ 2,000 ọrụ nke ịsọ ụlọ ịsọ nke ọkụ.
CDP357KVA bụ ịdọkọ dị ụtọ nke Jiuan Generator nke 357KVA nke Perkins nke eji eme ihe dị ka ịdọkọ nke ụlọ dị mkpa. E jiri Perkins 1706A-E93TAG1 — engine nke isi asaa, 9.3L nke eji ihe nchịkwa elektronik nke ihe nchịkwa na-eme ihe — eme ya, ịdọkọ ahụ na-eme 285KW/357KVA ISO8528 ESP nke ịdọkọ dị ụtọ ma ọ bụ 245KW/306KVA nke ịdọkọ dị mkpa, na ịdọkọ dị ụtọ nke 16% nke ịdọkọ dị mkpa maka ịdọkọ nke motor nke e ji eme ihe nke ATS. Ihe nchịkwa nke akwụkwọ: 58.5 L/h na ịdọkọ dị ụtọ nke 100%; tank nke akwụkwọ nke 500L maka 8+ oru nke ịdọkọ dị mkpa. EU Stage II / EPA Tier 2; canopy dị ụtọ ≤75dB(A) na 7m; warranty nke 18 ọnwa.